The molecular answer your oncology decision depends on.
Every cancer leaves a print.
Comprehensive genomic profiling, ctDNA and residual-disease monitoring,
pharmacogenomics and digital pathology — assembled into one report a
tumour board can act on, in Vietnamese and English.
ISO 15189 quality systemBilingual reporting — Vietnamese & EnglishBHYT claim codes on every reportMolecular tumour board review
Services
What we test, and what you get back
Every assay below is reported through one case record, so a
result never arrives as a loose page somebody has to reconcile by hand.
Comprehensive genomic profiling
Targeted next-generation sequencing across the actionable landscape of solid tumours, from FFPE tissue.
SNV, indel, copy number and fusion in one run
Tumour mutational burden and microsatellite status
Variant tiering to AMP/ASCO/CAP
ctDNA & residual disease
Circulating tumour DNA from blood, with serial draws tracked against a baseline so a trend is visible rather than inferred.
Personalised assay designed from the baseline tumour
Every result carries its limit of detection
Longitudinal MRD monitoring
Immunohistochemistry & ISH
Protein expression and copy-number confirmation on the bench, read on the scanner and recorded against the same case.
Predictive and diagnostic panels
Dual-colour in-situ hybridisation
AI-proposed counts, confirmed by a pathologist
Pharmacogenomics
Dose-critical genotypes read before the first cycle, not after a reaction — with the limitation stated in plain language.
DPYD, TPMT, NUDT15, UGT1A1
Activity scores and dosing guidance
Ancestry limitations stated, never silently passed
Digital pathology
Whole-slide scanning at diagnostic resolution, so a second opinion does not depend on couriering glass.
40× whole-slide imaging
Region-of-interest annotation
Slides viewable alongside the molecular result
Molecular tumour board
Complex cases reviewed by a panel before release, with each member's position recorded independently of the others.
Independent pre-review positions
Documented board decision
Therapy and trial matching
How it works
From specimen to signed report
Four stages, and you can see which one a case is in at any
moment — including which assays are still outstanding.
Order & accession
Order electronically or on paper. The specimen is received, checked and given an accession number the case keeps for life.
Assay
Extraction, library preparation and sequencing, or the bench assay the order calls for — each with its own quality control.
Interpret
Variants are tiered against current evidence, a scientist prepares the interpretation, and complex cases go to the board.
Sign out
A pathologist signs. The report is immutable from that moment; a correction is an amendment that names what changed.
A report is only released when the case is complete.
If an ordered assay has not come back, the case says so rather than
releasing a partial answer that reads like a whole one.
523genes on the comprehensive panel
7–10working days to sign-out
2languages on every report
100%of cases audit-logged end to end
The platform
Built so a wrong report is hard to produce
Most laboratory software is a filing cabinet with a login. Ours enforces
the rules a laboratory actually runs on, and refuses the actions that
would break them.
Only a pathologist may sign out — the authorisation table, not a convention
A signed report cannot be edited, even by a connection holding the database password
An override without a reason is refused, because it is not a decision
Every hospital's data is isolated at the database, not by a filter somebody has to remember
Results that arrive unmatched go to a reconciliation queue instead of the wrong case
Who we serve
Hospitals, cancer centres, and individuals
For hospitals & cancer centres
A managed molecular service that plugs into how your
department already works, without asking it to change.
Your own workspace, your own users, your own letterhead
Electronic ordering, or keyed from paper when a feed is not available
Results delivered back to your system, or read in the portal
Named scientific contact and turnaround commitments
Consolidated monthly billing with BHYT codes derived from what was performed
The result you can act on, or a refusal that says why
A laboratory is judged on the results it declines to release as much as
on the ones it signs. Ours are governed by rules in the software, not by
who happens to be on shift.
ISO 15189-aligned quality management system
External quality assessment rounds, tracked to closure
Validation dossiers held per assay, with an accredited scope
Run-level failures block every sample on the run, not just the obvious one
A limitation that applies is printed in full, never reduced to a flag
Common questions
Before you send us a specimen
What sample do you need?
For tissue testing, an FFPE block or unstained sections with a
representative tumour area. For ctDNA, blood in the tubes we supply.
If you are not sure the sample is adequate, send it and we will assess
it before anything is billed.
How long does a result take?
Seven to ten working days from receipt for comprehensive genomic
profiling; faster for single-gene and pharmacogenomic assays. If a case
is going to miss its commitment you are told before the date, not after.
Can we order without an electronic interface?
Yes. Orders can be keyed by our accessioning team from a paper
request form, and the case then behaves exactly like any other. An
interface can be added later without disturbing anything already running.
Who can see our patients' data?
Only your own users. Isolation is enforced at the database row, so a
query that tried to reach another organisation's cases returns nothing
rather than relying on a filter somebody remembered to apply.
Do you report in Vietnamese?
Every report is bilingual — Vietnamese and English in the same
document, so the same page serves the treating team, the patient, and
an international second opinion.
Is the test covered by BHYT?
Coverage depends on the assay and the indication. Claim codes are
derived from what was actually performed and printed on the report, so a
claim is not assembled by guesswork. We will confirm the position for
your case before it runs.
Contact
Talk to the laboratory
A scientist answers these, not a call centre. If your
question is clinical and urgent, telephone rather than write.
Clinical & scientific enquiriesMonday to Saturday, 07:30–17:30 (ICT)
Written enquiriesAnswered within one working day
Specimen receptionCouriered samples accepted during opening hours
Existing casesSign in to the portal for status and reports
This form is not for clinical urgencies. If a patient
needs a decision today, telephone the laboratory so a scientist can
pick it up immediately.